| Technical Specifications | |
|---|---|
| Design & Manufacturing | QB/T12239-89 BS5156 |
| Design Standards | JB/T82.1-94 GB9113.3-88 |
| Face-to-Face Dimensions | GB12221-89 |
| Inspection & Testing Standards | GB/T13927-92 |
| Technical Parameter | |
|---|---|
| Nominal Diameter (DN) | DN15~DN150 |
| Connection Type | Flanged |
| Actuator Sizing | Gemü-type piston actuator (spring return) or diaphragm actuator |
| Control Method | 2-position shut-off (ON/OFF) or modulating control |
| Nominal Pressure (PN) | 6bar、16bar |
| Supply Pressure | 5~7bar |
| Media Temperature | -29~160℃ |
| Ambient Temperature | -20~60℃ |
| Body Material | Carbon steel (C), Stainless steel (P, PM, PL) |
| Seat/Seal Material | EPDM+PTFE |

| Main connection dimensions | |||||||
|---|---|---|---|---|---|---|---|
| Nominal Diameter (DN) | H (High) | D1 (Flange outer diameter) | D (Diameter of flange screw hole) | L (Valve body length) | n (Number of flange holes) | C (Hole size) | B (Flange thickness) |
| 15 | 215 | 65 | 95 | 125 | 4 | 14 | 14 |
| 20 | 220 | 75 | 105 | 135 | 4 | 14 | 16 |
| 25 | 225 | 85 | 115 | 145 | 4 | 14 | 16 |
| 32 | 240 | 100 | 135 | 160 | 4 | 18 | 16 |
| 40 | 285 | 110 | 145 | 180 | 4 | 18 | 16 |
| 50 | 307 | 125 | 160 | 210 | 4 | 18 | 18 |
| 65 | 327 | 145 | 180 | 250 | 4 | 18 | 22 |
| 80 | 390 | 160 | 195 | 300 | 4 | 18 | 25 |
| 100 | 470 | 180 | 215 | 350 | 8 | 18 | 25 |
| 125 | 637 | 210 | 245 | 400 | 8 | 18 | 30 |
| 150 | 240 | 280 | 460 | 8 | 23 | 30 | |
| 200 | 295 | 335 | 570 | 8 | 23 | 35 | |
| Attachment selection | |
|---|---|
| Solenoid valve | For double-acting, select 2-position 5-way; for single-acting, select 2-position 3-way.Specify single solenoid control or double solenoid control when placing an order. |
| Pneumatic filter regulator lubricator (FRL unit) | Stabilizes air pressure, filters air source, and lubricates cylinders. |
| Limit switch | Provides remote feedback of switch signals. |
| Manual operating mechanism | Enables manual opening and closing of the valve. |
| Positioner | Inputs analog signals (4-20mA or 0-10V) to regulate the valve opening. |
We Are Glad to Receive Your